Login|Register|Forget password|Dashboard Back to Home|Contact|Shopcart
Unverified1st Year

QINGDAO BILIN ELECTRICAL APPLIANCES CO., LTD.  

Search
新闻中心
  • 暂无新闻
产品分类
  • 暂无分类
联系方式
  • 联系人:Miss Arissa
  • 电话:86-18661973259
  • 传真:86-532-83182680
站内搜索
 
荣誉资质
  • 暂未上传
友情链接
  • 暂无链接
首页 > Products > Medical Equipments Mobile ICU Pediatric Anaesthesia Ventilator Machine Oxygen Ventilators Breathing
Medical Equipments Mobile ICU Pediatric Anaesthesia Ventilator Machine Oxygen Ventilators Breathing
单价 面议对比
询价 暂无
浏览 41
发货 Chinashandongqingdao
过期 长期有效
更新 2020-05-06 15:59
 
详细信息
Product Name: Medical Equipments Mobile ICU Pediatric Anaesthesia Ventilator Machine Oxygen Ventilators Breathing Machine Certification: CE Product Description Medical Equipments Mobile Energy Recovery ICU Pediatric Anaesthesia Ventilator Machine Oxygen VentilatorsVentilator is a model of multi-purpose life-support machine.This machine uses the air operated electric control, the microcomputer technology. Selects imports the primary device to guarantee the equipment movement stably reliable. Colored (TFT) the screen demonstrates each kind of examination and the establishment parameter, which is a section of ideal breath treatment plant. It is suitable in all different levels of hospitals for internal medicine of surgery, gynecology, pedology, first aid, ICU and so on which are administrative offices equipments.Main technical parametersVentilatorDisplay mode10.4-inch High-definition TFT color LCD screen displayVentilation modeVCV,PCV,SIMV,PSV,PSV+SIMV,CPAPVentilation functionPEEP,SIGH,standby,IP,IRVVentilation parametersTidal volume20~2000mlRate2~120bpmSIMV rate2~20bpmI:E4:1~1:8Inspiratory trigger pressure-10~20 cmH2OFlow trigger sensitivity1-20L/minPEEP0~25cmH2OPressure control3~60cmH2OPresure limit5~60cmH2OPressure slope1~10 gearFlow rate setting1~10 gearExpiratory trigger sensitivity10%~90%Time control1~10sSIGH1.5 times the inspiratory time(60-120 times adjustable)Inspiratory platform0~50%Oxygen concentration21%~99%Parameters for ventilation monitoringOxygen Concentration alarmUpper limit setting range21%~99%Low limit setting range15%~80%Airway pressure alarmUpper limit setting range1~60 cmH2OLow limit setting range0~50 cmH2OMinute ventilation volume alarmUpper limit setting range1~30L/minLow limit setting range0~20L/minTidal volumeUpper limit setting range10~2000mlLow limit setting range0~1800mlRespiratory rateUpper limit setting range10~99bPmLow limit setting range0~50 bPmSustained high-pressure alarmit will give alarm when stress have consistently been higher than 30 cmH2OSuffocation alarmGas shortage alarmLow pressure of Oxygen alarmLow pressure of Air alarmPower alarmIntubation off alarmBattery voltage alarmPowerAC 220V±10% 50Hz±1Hz UPS, Storage BatteryManipulator